The publication is also available in french as nf en 1822. En 1822s five parts define salient characteristics for hepaulpa filters. Classification, performance testing, marking filtres a air a haute efficacite epa, hepa et ulpa. The revised standard will make reference to parts 25 of. Classification, performance testing, marking foreign standard the document applies for high efficiency air. April 2008 draft document draft document high efficiency air filters epa, hepa and ulpa part 1. Filters must be tested with an air flow rate between 0.
Coarse filters average arrestance am final test pressure drop 250 pa medium and fine filters average efficiency em and minimum efficiencym. 2012 air flow range for testing 850 m 3h 5000 m3h standard air flow is 3400 m3h for complete filter units 592mmx592mm pocket filter compact filter. In order to cope with the demands of high technology, there is a need for new testing methods and a new classification of absolute filters din. Dec 24, 2018 for membrane filter media, separate rules apply, see annex a of en 1822 5.
Classification, performance testing, marking original english text of csn en standard. The twopart en 1822 test identifies the mpps and challenges the filter with only these particles. Set en 1822 and en iso 29463 standards for heigh efficiency air filters epa, hepa and ulpa saving is 62 compared to buying individual titles. Find the most uptodate version of en 18221 at engineering360. Cen en 18221 high efficiency air filters epa, hepa and. Seamless and welded steel tubes dimensions and masses. For membrane filter media, separate rules apply, see annex a of en 18225.
The national interests during the preparation of the standard were represented by the mechanical engineering standards committee nam, technical section general. Determining the efficiency of filter elements withdrawn from 02. Hepa and ulpa filters are also subject to individual tests, with testing based on the latest particle counting methods. Iso 29463 new standard for epa, hepa and ulpa filters. This part of en 1822 applies to the leak testing of filter elements. At the european level, however, en 18221 classification, performance testing, marking will continue to exist in a revised version. Ssen18224 high efficiency air filters epa, hepa and. Primarily used to certify air filters for clean room applications. Comparison of filter classes according en 779, en 1822 and. In europe, these filters are subject to classification according to en 1822.
Absolute filters epa, hepa and ulpa filter classification to hepa and ulpa filters, the classification is based on eurovent 44 standard which defines 5 types of filters. The new eurovent classification is defined in rating standard rs4c0012019 and covers all products in the scope of the eurovent certified performance programme for air filters rated at 0. Principal of en 779 testing, coarse filter criteria en 779. Cen en 18221 high efficiency air filters epa, hepa. New iso classification systems and standards how do. The national interests during the preparation of the standard were represented by the mechanical engineering standards committee nam, technical section. After processing this data, the size of the particle, for which the efficiency of the medium is minimal, can be determined. Classification, performance testing, marking this document applies to high efficiency particulate and ultralow penetration air filters epa, hepa and ulpa used in the field of ventilation and air conditioning and for technical processes, e. En 1822 and iso 29463 in europe, epa, hepa and ulpa filters are subject to classification according to en 1822 for filtration efficiency and zero leakage. Din en 18221 high efficiency air filters epa, hepa and ulpa part 1.
An alternative method for leakage testing of group h filters with shapes other than panels. The new en 1822 standard replaces, under european law, all national test standards for hepaulpa filters, such as bs 3928, din 24184 or afnor nf x440. Major innovations introduced by en 1822 include the use of modern particlecounting technology and determination of collection efficiency in the collection efficiency minimum. Coarse filters average arrestance am final test pressure drop 250 pa medium and fine filters average efficiency. The international standard iso 29463 is based on european standard en 1822 and will probably replace this standard in the future. The scan method which is described in detail regarding procedure, apparatus and test conditions in the body of this. Bs en 18221 complete document 2009 edition, december 31, 9. By using a particle contactor, the number and size of the particles trapped by the filter can be determined. This method also allows testing ultra low penetration air filters, which was not possible with. The uk participation in its preparation was entrusted to technical committee mce2, air filters other than for air supply for i. Iso 16890 is the current international standard for testing air filters for ventilation systems in the food and beverage industry.
The price of the standard included all amendments and correcturs. The scan method which is described in detail regarding procedure, apparatus and test conditions in the body of this standard is valid for the complete range ofgroup h and u filters and is considered to be the reference test method for leak determination. Swedish standards corresponding to documents referred to in this standard are listed in catalogue of swedish standards, issued by sis. Bs en british standard high efficiency air filters epa. En 18221 en 18221 high efficiency air filters epa, hepa and ulpa part 1. All bsi british standards available online in electronic and print formats. Definition of filtration performance from en 779 to iso. Intended to provide clarity in this maze of standards, iso 29463 is derived from en 1822, which defines the epa, hepa and ulpa filter classes commonly found in industrial use. This document contains the official english version of en 18221.
The averaged efficiency of the filter is called overall, and the efficiency at a specific point is called local. Compliance with a british standard cannot confer immunity from legal obligations. Bs en british standard high efficiency air filters epa, hepa. Classification of air filters freudenberg filtration. Classification, performance testing, marking foreign standard the document applies for high efficiency air filters used in the field of ventilation and air conditioning and for technical processes, in particular for clean room technology. Hepa and ulpa filters are also subject to individual tests. Seamless and welded steel tubes dimensions and masses per. This method also allows testing ultra low penetration air filters, which was not possible with the previous test methods because of their inadequate sensitivity. Hepa and ulpa filters are also subject to individual tests, with. The revised standard will make reference to parts 25 of iso 29463.
Standards en 1822 and en iso 29463 epa, hepa and ulpa. En 1822 1 en 1822 1 high efficiency air filters epa, hepa and ulpa part 1. Cen en 18221 high efficiency air filters epa, hepa and ulpa part 1. The new series of bs en 1822 high efficiency air filters epa, hepa and ulpa has been published in january 2011. Put in simple terms, en 1822 will have its own classification system part 1 for air filters but will test them according to iso 29463 parts 25. A new iso standard is about to replace the current en 779 standard used to characterize the filtration efficiency of filters now classified from g1 to f9. At the european level, however, en 1822 1 classification, performance testing, marking will continue to exist in a revised version. Classification, performance testing, marking this document applies to high efficiency particulate and ultralow penetration air filters epa. The new standard has its roots in en 1822, and defines different filter classes ranging from iso 15 e to iso 75 u. This european standard is applied to air filters with an initial efficiency below 98% for 0. Hepa filters, as defined by the united states department of energy doe standard adopted by most american industries, remove at least 99. When the new standard en 1822 hepaulpa filters came into force, it constituted an important step forward for cleanroom technology in europe.